Direct Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation Processing

Product Details
Customization: Available
Type: Water-Cooled
Cooling Method: Water-cooled
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (29)
  • Direct Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation Processing
  • Direct Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation Processing
  • Direct Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation Processing
  • Direct Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation Processing
Find Similar Products
  • Overview
  • Main Produsct
  • Product Description
  • Applications&Successful Cases
  • Company Profile
  • Packaging & Shipping
Overview

Basic Info.

Unit Structure
Integral
Selected Voltage
380V/50HZ
Compressor Number
2
Noise Level
Low
Application Fields
Aluminum Profile Anodizing
Application Machine
CNC Machine Tools
Certification
ISO, CE, CCC
Condition
New
Brand Name
Kingfit
Application
Industrial Cooling
Place of Origin
China, Zhejiang
Power
150ton-300ton
Transport Package
Wooden Case
Specification
QLC220SMAZ
Trademark
KINGFIT
Origin
Zhejiang China
HS Code
84186990
Production Capacity
20 Set/Quarter

Product Description

Direct Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation Processing

Main Produsct

Direct Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation Processing

Product Description

Direct Cooling Falling-film Magnetic Levitation Centrifugal (Chiller)

Features:
Quiet operation with ultra low noise magnetic bearing technology is used in compressors. Main shafts of the compressors rotate at high speed without any mechanical contact.
Oil-free design to reduce costs. Oil-free operation eliminates complicated oil system, reducing operational and maintenance costs.
Redundancy design and efficient operation. Multiple compressors are installed on a shared evap. and cond., providing redundancy to ensure efficient operation of the equipment.
High energy efficiency and short payback period. Compared to conventional chillers, KINGFIT oil-free chillers can save 42% or even more operational costs with a payback period of just 2-3 years.
Environmental friendly, clean and safe. Use environmental friendly refrigerant R134a with zero ODP.
Intelligent control and high efficiency management. Unique PLC features adaptive control logic enables real-time optimization of the system to maintain best efficiency. Control panel has functions of capacity control, status display, fault diagnosis and other automatic control feature to ensure high efficiency management.

Outlet temperature is accurate to + 0.1 degree C, adopting HFC-134a refrigerant is green and environmental friendly, safe and non-toxic.
No need plate heat exchanger, chilled water pump and chilled water tank, save investment cost, so as to avoid waste of cooling capacity.
Starting current is 1~2a≈1 bulb, almost no impact on the power grid.
Using high efficiency falling-film evaporator, heat exchange efficiency is higher, less refrigerant to be charged.
No oil operation, no oil circuit maintenance, high efficiency, power consumption 40KWH per ton of national standard product, compared to the sixth generation flooded type magnetic levitation centrifugal chiller, the energy saving rate more than 20%.
 
Performance comparison
Direct-cooling magnetic levitation frequency centrifugal chiller design life of 30 years, while the screw chiller design life of 15 years.
The impeller of the magnetic levitation centrifugal chiller is directly driven. There is only one moving component in the compressor, and the fault is fewer. The ordinary screw chiller has complex transmission and higher failure rate.
The whole life of the magnetic levitation centrifugal chiller is no need of oil circuit maintenance, while the screw chiller need oil circuit maintenance at least once a year
Magnetic levitation chiller temperature control accuracy is up to 0.1ºC, while screw chiller is only 0.5ºC
The maximum rotation speed of magnetic levitation is 48000RPM, while the maximum rotation speed of screw chiller is 2950RPM.
The energy efficiency ratio(EER) of the direct-cooling oxidation working condition  of the magnetic levitation unit can reach more than 15, while the direct-cooling screw chiller is about 7.2.
Using falling-film evaporator, refrigerant charge is less than flooded type, much lower maintenance costs.
 
The refrigerant in the falling film evaporator is sprayed from the upper part of the heat exchanger to the heat exchange tube. The refrigerant only forms a thin layer of refrigerant liquid film on the heat exchange tube, so that when the refrigerant evaporates, Reducing the static level pressure, thereby improving the heat exchange efficiency, the heat exchange efficiency is increased more than 3 times than the flooded type unit.
The charged refrigerant of the falling film magnetic levitation centrifugal chiller is much less, only 50% of the flooded type. Reducing the maintenance cost at later stage.
 
With KINGFIT's self-developed remote control system, you can have your refrigeration system under 24-hour remote management by simply login through the dedicated window of our official website; with functions of remote warning on hidden operational risks and remote transmission of failure alarm, the remote control system can serve as an exclusive housekeeper of your refrigeration system that solves all your worries in a comprehensive manner.
 
 
Water pump and acid pump group control.
Kingfit according to the process of profile oxidation production, acid pump, cooling tower, cooling water pump and other equipments are not based on actual needs of long-term full load operation, a serious waste of energy, increases operating costs. Developing of the intelligent oxidation pump station, using Kingfit independently researched and developed software, through the inverter, proportional flow valve, temperature sensor, dry and wet bulb detector, frequency changing pump, weather station and other equipments real-time detection equipment required load demand, Adjusting energy consumption of the equipment operation, both meet the using requirements and save much more enenrgy, compared to the traditional system as a whole more than 20% energy saving.
Acid pump frequency converting control, through monitoring the rectifier heat, control the proportion of flow valve opening, according to the actual cooling capacity requirment of the tank liquid, adjusting the operating power of the acid pump so as to reduce energy consumption.
Cooling water pump frequency converting control, through the weather station real-time monitoring of outdoor air temperature and cooling water temperature, to adjust the pump rotation speed, while meet the cooling requirment of chiller as well as  reduce the  running energy consumption to a minimum.
The cooling tower fan frequency converting control, through the weather station to collect outdoor wet bulb temperature and dry bulb temperature, once the cooling water temperature reaches the limit temperature, adjust the fan speed, perfectly reduce energy waste.
The pump station system will mix the tank liquid and balance the tank liquid concentration and improve the process performance.
KINGFIT gather all the equipments into a product, while saving energy, at the same time, the overall equipment is more compact, reduce the space and customers only need to connect the main channel to the intelligent oxidation pump station interface, for the customers to avoid the trouble of the pipeline installation.
Intelligent oxidation pump station system through the falling film magnetic levitation centrifugal chiller intelligent integrated control, making the equipment to run more energy saving and stable.
Falling film type magnetic levitation chiller and water pump acid pumps are group controlled system.

 

Applications&Successful Cases

Direct Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation ProcessingDirect Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation Processing

Company Profile

Direct Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation Processing   Here is a true story of the founding brothers of KINGFIT - just a couple of ordinary boys who started out small in 1998 to pursue their big vision to explore and meet the real needs of the market, offering unprecedented solutions in terms of customization, innovation, and efficiency. Their steadfast commitment to bring the best lead to revolutionizing the industry and triggering widespread success in the market.
  
 The new millennium brought our company a constantly growing reputation that propelled us beyond the national borders with a greater purpose. Fully understanding our customers and business partners to provide tailor-made solutions that best fit their requirements allowed KINGFIT to grow exponentially. That lead the company to develop an extensive knowledge of an ample range of industries, pushing KINGFIT to branch out into three major markets with a vast array of intelligent and energy-efficient climate solutions for agriculture, temperature solutions for various industries, and air conditioning systems around the globe.
   Today KINGFIT is run by an ever-expanding brilliant team of hundreds of passionate professionals with an unchanged vision to persistently improve at all levels - serving customers with the unparalleled quality and efficiency we've become renowned for in the last 23 years. And continues to meet and exceed all our customer's rising expectations, and support them on the journey towards a world where only real Efficiency can guarantee a truly Sustainable Future for everyone.
Direct Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation ProcessingDirect Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation Processing

Packaging & Shipping

Direct Cooling Falling-Film Magnetic Bearing Centrifugal Chiller for Oxidation Processing

 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier